Tripp Lite SU80K3/3INTPM SmartOnline 3-Phase UPS System

Tripp Lite Updated: 2009-01-25 RSS
Tripp Lite SU80K3/3INTPM SmartOnline 3-Phase UPS System

Tripp Lite's SU80K3/3INTPM SmartOnline 3-Phase Intelligent, True On-Line UPS System provides mission-critical equipment with the highest level of power protection available. Large capacity 80,000 VA/64,000 watt power module continually converts incoming AC power into filtered DC power, and then resynthesizes it back into pure sine wave 3-phase AC power. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. Unit can be paralleled with up to eight power modules without requiring extra control cards. Hot standby option increases the availability of connected equipment by reducing the chance that a failure of one UPS might impact output power. IGBT inverter technology produces output power with <3% THD (total harmonic distortion) for peak performance of connected equipment. A 3:1 crest factor safely supports a variety of equipment, even equipment with wildly-fluctuating power demands. Extremely efficient operation (up to 97% efficiency in Economy Mode) saves money by reducing electricity consumption. Hardwire input and output connections support a variety of permanent or PDU style power connections. Features 3-phase user-selectable 220/380 or 230/400 or 240/415V AC input and output. Wide input voltage correction range (176-288/304-499V AC). Frequency is 50 or 60 Hz (auto-selectable). Includes a power module in a tower format cabinet. A variety of battery modules can be selected to match battery backup runtime and other requirements. Manual and automatic bypass functions ensure maximum availability of connected equipment by safely passing through AC power if the power module requires maintenance. Three built-in, simultaneously addressable communication ports (RS-232, contact closure and AS-400) work with included PowerAlert Software to provide automatic shutdown commands and monitoring for multiple servers. An accessory slot accepts an optional internal SNMP card (model # SNMPWEBCARD) that provides an Ethernet connection for IP network-based remote monitoring and control via SNMP, Web browser or telnet, enabling remote shutdowns, reboots and more. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions.

* True on-line, double conversion UPS provides pure sine wave AC output at all times
* Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time to battery
* Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
* 80,000 VA/64,000 watt power capacity with hardwire input/output connections
* 3-phase user-selectable 220/380 or 230/400 or 240/415V AC input and output. Wide input voltage correction range (176-288/304-499V AC)
* Standard battery module BP348V66 (ordered separately) provides 13 minutes runtime at half load (32,000 watts) and 4 minutes runtime at full load (64,000 watts)
* 3:1 crest factor safely supports a variety of equipment, even equipment with wildly-fluctuating power demands
* Extremely efficient operation (up to 97% efficiency in Economy Mode) saves money by lowering electricity consumption
* Expandable runtime with multiple external battery modules (contact Tripp Lite); custom runtime/battery solutions available
* 3 communication ports (RS-232, contact closure and AS-400)
* Slot for optional SNMP card (model # SNMPWEBCARD)
* Manual and automatic bypass functions ensure maximum availability of connected equipment by safely passing through AC power if the power module requires maintenance
* Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval
* Emergency Power Off button turns UPS output OFF and disables bypass output
* PowerAlert Universal UPS Power Management Software and communication cabling included
* Built-in event log to assist in power evaluation and troubleshooting
* Control panel with combination LCD/LED display
* Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities
* Parallel up to 8 modules without additional control cards
* Dual inputs - mains and bypass
* Output isolation transformer
* 2-year power module and 1-year batteries limited repair or replacement warranty

Applications

* Ideal for protecting critical 220/380 or 230/400 or 240/415V equipment in industrial environments, data centers, server clusters, networking/internetworking and telecommunications systems.

Package Includes

* SU80K3/3INTPM UPS System (power module)
* PowerAlert Software and cabling
* Warranty information
* Instruction manual