Konica Minolta Regius Model 370 DR System

Konica Minolta Updated: 2008-12-23 RSS
Konica Minolta Regius Model 370 DR System

The REGIUS 370 DR is an upright digital radiography system capable of supporting a wide range of clinical applications. The heart of the REGIUS 370 DR is Konica Minolta's patented new Plate technology. This new Plate is an advanced Cesium Bromide (CsBr) phosphor detector with a columnar structure that rivals the detective quantum efficiency (DQE) found in solid state DR systems.

Combining our plate with new anti-backscatter techniques, customizable image processing algorithms and on-site integration with your existing X-ray suite, the REGIUS 370 DR system allows you to "go digital" while protecting your current investment in existing radiographic equipment.

* Compact footprint
* Versatile clinical applications (6 exposure sizes, 3 positions, 2 orientations, from 17x17 to 8x10) all from a single embedded CR detector
* Fully automated with x-ray equipment for optimal workflow
* Fast! 16 second cycle time, 210 exposures per hour
* 12 bit grayscale dynamic range
* Compatible with major OEM x-ray equipment to extend current investments

Direct Digitizer REGIUS Vstage MODEL370 (DD-841)*
Exposure size: 17"×17" 14"×17" 17"×14" 14"×14" 11"×14"
14"×11" 10"×12" 12"×10" 8"×10" 10"×8"
Sampling pitch: 87.5μm/175μm
Exposure cycle time: Approx. 16 seconds (all sizes, 175μm)
Processing capability: Approx. 210 sheets/hour (all sizes, 175μm)
Maximum resolution: 4860×4860 (17"×17")
No. of digital gradation levels: 4096 levels (12bits)
Outer dimensions/Weight: W800×D560×H1700mm/approx. 330kg
Power Consumption: Single-phase 100V/200V (Option) Approx. 1.0kW 50/60Hz
Operating conditions: Temperature:15~30
Humidity:40~80% (no condensation)
Accessories: Hand grip for anterior exposure,
Hand grip for lateral exposure, Foot switch,
Reader controller connecting cable set
Main options: Auto collimation board, Lead apron arm,
Casette holder, 200V Power cable

Multi-reader control
One CS-3 unit seamlessly controls both reader units of the Model190 and Model 370. For superior processing continuity, the flow of exposures is uninterrupted while the images are acquired.

Freely Selectable Reader
Images are always displayed on the CS-3 where the plate is registered, regardless of which the reader unit used to scan the plate. This makes it easier for the operator to check image quality while maximizing the reader utilization.
A better real-time display

User Tool
Shorter time from exposure to image checking is important for the user's efficiency. The CS-3 makes it possible to check the image in the least amount of time possible, since images are displayed in real time.

User Tool
This tool allows the user to modify processing parameter settings, examination key layout, and other settings with ease. The operation is highly visually oriented:users can browse previous images while using slide bars to change the settings;images are then updated as the settings change. The drop and drag function for creating examination keys are also intuitive and simple to use.